Initial check-in
This commit is contained in:
@@ -0,0 +1,139 @@
|
||||
/*-------------------------------------------------------------------------
|
||||
// UNCLASSIFIED
|
||||
/*-------------------------------------------------------------------------
|
||||
RAYTHEON PROPRIETARY: THIS DOCUMENT CONTAINS DATA OR INFORMATION
|
||||
PROPRIETARY TO RAYTHEON COMPANY AND IS RESTRICTED TO USE ONLY BY PERSONS
|
||||
AUTHORIZED BY RAYTHEON COMPANY IN WRITING TO USE IT. DISCLOSURE TO
|
||||
UNAUTHORIZED PERSONS WOULD LIKELY CAUSE SUBSTANTIAL COMPETITIVE HARM TO
|
||||
RAYTHEON COMPANY'S BUSINESS POSITION. NEITHER SAID DOCUMENT NOR ITS
|
||||
CONTENTS SHALL BE FURNISHED OR DISCLOSED TO OR COPIED OR USED BY PERSONS
|
||||
OUTSIDE RAYTHEON COMPANY WITHOUT THE EXPRESS WRITTEN APPROVAL OF RAYTHEON
|
||||
COMPANY.
|
||||
|
||||
THIS PROPRIETARY NOTICE IS NOT APPLICABLE IF DELIVERED TO THE U.S.
|
||||
GOVERNMENT.
|
||||
|
||||
UNPUBLISHED WORK - COPYRIGHT RAYTHEON COMPANY.
|
||||
-------------------------------------------------------------------------*/
|
||||
using NLog;
|
||||
using Raytheon.Common;
|
||||
using Raytheon.Instruments;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Drawing;
|
||||
using System.Threading;
|
||||
using System.Threading.Tasks;
|
||||
|
||||
namespace Raytheon
|
||||
{
|
||||
/// <summary>
|
||||
/// Class for controlling all power supplies
|
||||
/// </summary>
|
||||
public class PowerModuleMeasurementManager
|
||||
{
|
||||
#region PrivateClassMembers
|
||||
/// <summary>
|
||||
/// NLog logger
|
||||
/// </summary>
|
||||
private static NLog.ILogger _logger;
|
||||
|
||||
private PowerSupply _powerSupply;
|
||||
|
||||
private IConfigurationFile _powerOffAndSelfTestConfig;
|
||||
|
||||
#endregion
|
||||
|
||||
public bool FrontPanelEnabled
|
||||
{
|
||||
get
|
||||
{
|
||||
if (_powerSupply != null)
|
||||
{
|
||||
return _powerSupply[null].FrontPanelEnabled;
|
||||
}
|
||||
else
|
||||
return true;
|
||||
}
|
||||
|
||||
set
|
||||
{
|
||||
if (_powerSupply != null)
|
||||
{
|
||||
_powerSupply[null].FrontPanelEnabled = value;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// constructor
|
||||
/// </summary>
|
||||
/// <param name="stePowerSupplyInstanceName">the name specified in the Instruments.xml file</param>
|
||||
public PowerModuleMeasurementManager(PowerSupply powerSupply, IConfigurationFile powerOffAndSelfTestConfig)
|
||||
{
|
||||
_logger = LogManager.GetCurrentClassLogger();
|
||||
|
||||
_powerSupply = powerSupply;
|
||||
_powerOffAndSelfTestConfig = powerOffAndSelfTestConfig;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The Finalizer
|
||||
/// </summary>
|
||||
~PowerModuleMeasurementManager()
|
||||
{
|
||||
_logger?.Debug($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() ...");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Initialize the instrument(s)
|
||||
/// </summary>
|
||||
public void Initialize()
|
||||
{
|
||||
_logger.Trace($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() method...");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Shuts down manager, clears resources
|
||||
/// </summary>
|
||||
public void Shutdown()
|
||||
{
|
||||
_logger?.Debug($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() method...");
|
||||
_powerSupply.Shutdown();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Read various power supply data
|
||||
/// </summary>
|
||||
public void ReadPowerSupplyData(object module, out double voltage, out double current, out double voltageSetPoint, out bool isOn, out int faultStatus)
|
||||
{
|
||||
_powerSupply[module].ReadPowerSupplyData(out voltage, out current, out voltageSetPoint, out isOn, out faultStatus);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Enable the output of the power supply.
|
||||
/// </summary>
|
||||
/// <param name="moduleName">The name of the module to enable.</param>
|
||||
public void OutputEnable(object module)
|
||||
{
|
||||
_powerSupply[module].On();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Disable the output of the power supply.
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
public void OutputDisable(object module)
|
||||
{
|
||||
_powerSupply[module].ReadPowerSupplyData(out double voltage, out double current, out double voltageSetPoint, out bool isOn, out int faultStatus);
|
||||
|
||||
if (isOn)
|
||||
{
|
||||
_powerSupply[module].Off();
|
||||
|
||||
// save the time of this power off to file
|
||||
MeasurementManager.PowerSupply.Util.SaveTime(_powerSupply.Name, DateTime.Now.ToString(), null, _powerOffAndSelfTestConfig);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,218 @@
|
||||
/*-------------------------------------------------------------------------
|
||||
// UNCLASSIFIED
|
||||
/*-------------------------------------------------------------------------
|
||||
RAYTHEON PROPRIETARY: THIS DOCUMENT CONTAINS DATA OR INFORMATION
|
||||
PROPRIETARY TO RAYTHEON COMPANY AND IS RESTRICTED TO USE ONLY BY PERSONS
|
||||
AUTHORIZED BY RAYTHEON COMPANY IN WRITING TO USE IT. DISCLOSURE TO
|
||||
UNAUTHORIZED PERSONS WOULD LIKELY CAUSE SUBSTANTIAL COMPETITIVE HARM TO
|
||||
RAYTHEON COMPANY'S BUSINESS POSITION. NEITHER SAID DOCUMENT NOR ITS
|
||||
CONTENTS SHALL BE FURNISHED OR DISCLOSED TO OR COPIED OR USED BY PERSONS
|
||||
OUTSIDE RAYTHEON COMPANY WITHOUT THE EXPRESS WRITTEN APPROVAL OF RAYTHEON
|
||||
COMPANY.
|
||||
|
||||
THIS PROPRIETARY NOTICE IS NOT APPLICABLE IF DELIVERED TO THE U.S.
|
||||
GOVERNMENT.
|
||||
|
||||
UNPUBLISHED WORK - COPYRIGHT RAYTHEON COMPANY.
|
||||
-------------------------------------------------------------------------*/
|
||||
using NLog;
|
||||
using Raytheon.Common;
|
||||
using Raytheon.Instruments;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Threading;
|
||||
using System.Threading.Tasks;
|
||||
|
||||
namespace Raytheon
|
||||
{
|
||||
/// <summary>
|
||||
/// Class for controlling all power supplies
|
||||
/// </summary>
|
||||
public class PowerSupplyMeasurementManager
|
||||
{
|
||||
#region PrivateClassMembers
|
||||
/// <summary>
|
||||
/// NLog logger
|
||||
/// </summary>
|
||||
private static NLog.ILogger _logger;
|
||||
|
||||
private IConfigurationFile _powerOffAndSelfTestConfig;
|
||||
|
||||
private IInstrumentManager _instrumentManager;
|
||||
|
||||
private Dictionary<string, PowerModuleMeasurementManager> _powerSystemNameToPowerModuleMeasurementManagerDict = new Dictionary<string, PowerModuleMeasurementManager>();
|
||||
|
||||
string _powerSystemWithFailedSelfTest = String.Empty;
|
||||
|
||||
#endregion
|
||||
|
||||
/// <summary>
|
||||
/// constructor
|
||||
/// </summary>
|
||||
/// <param name="stePowerSupplyInstanceName">the name specified in the Instruments.xml file</param>
|
||||
public PowerSupplyMeasurementManager(IInstrumentManager instrumentManager, string powerSupplySelfTestLogFile)
|
||||
{
|
||||
_logger = LogManager.GetCurrentClassLogger();
|
||||
|
||||
_powerOffAndSelfTestConfig = new ConfigurationFile(powerSupplySelfTestLogFile);
|
||||
|
||||
_instrumentManager = instrumentManager;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The Finalizer
|
||||
/// </summary>
|
||||
~PowerSupplyMeasurementManager()
|
||||
{
|
||||
_logger?.Debug($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() ...");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Implement Indexer to obtain a powermodulemeasurementmanager
|
||||
/// </summary>
|
||||
/// <param name=""></param>
|
||||
/// <returns></returns>
|
||||
public PowerModuleMeasurementManager this[object powerSystemId]
|
||||
{
|
||||
get
|
||||
{
|
||||
if (!powerSystemId.GetType().IsEnum)
|
||||
{
|
||||
throw new ArgumentException($"{nameof(powerSystemId)} must be an enumerated type");
|
||||
}
|
||||
|
||||
if (!_powerSystemNameToPowerModuleMeasurementManagerDict.ContainsKey(powerSystemId.ToString()))
|
||||
{
|
||||
throw new Exception($"Invalid power supply system: {powerSystemId.ToString()}");
|
||||
}
|
||||
|
||||
return _powerSystemNameToPowerModuleMeasurementManagerDict[powerSystemId.ToString()];
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Initialize the instrument(s)
|
||||
/// </summary>
|
||||
public void Initialize()
|
||||
{
|
||||
_logger.Trace($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() method...");
|
||||
|
||||
PerformSelfTest();
|
||||
|
||||
if (_powerSystemWithFailedSelfTest != String.Empty)
|
||||
{
|
||||
throw new Exception($"{_powerSystemWithFailedSelfTest}'s self-test failed.");
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Perform self test on power supply system
|
||||
/// Self test for each power system takes a while, so we don't want to run self test every time we initialize the power system
|
||||
/// So we only want to run self test under 2 conditions:
|
||||
/// 1. Certain time has elapsed since last power off
|
||||
/// 2. Certain time has elapsed since last self test run ( in the absence of power off time)
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
private async void PerformSelfTest()
|
||||
{
|
||||
_logger.Trace($"Entering {this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() method...");
|
||||
|
||||
string errorMsg = String.Empty;
|
||||
|
||||
Dictionary<string, Task<SelfTestResult>> powerSystemToSelfTestTaskDict = new Dictionary<string, Task<SelfTestResult>>();
|
||||
|
||||
bool allSelfTestsPassed = true;
|
||||
|
||||
ICollection<object> psList = _instrumentManager.GetInstruments(typeof(PowerSupply));
|
||||
|
||||
foreach (PowerSupply ps in psList)
|
||||
{
|
||||
ps.Initialize();
|
||||
|
||||
// perform self test on power system
|
||||
Task<SelfTestResult> task = PerformSelfTestTask(ps);
|
||||
powerSystemToSelfTestTaskDict[ps.Name] = task;
|
||||
}
|
||||
|
||||
foreach (var item in powerSystemToSelfTestTaskDict)
|
||||
{
|
||||
// wait for self test on power system to finish
|
||||
SelfTestResult result = await item.Value;
|
||||
|
||||
if (result == SelfTestResult.Fail && String.IsNullOrEmpty(_powerSystemWithFailedSelfTest))
|
||||
{
|
||||
allSelfTestsPassed = false;
|
||||
_powerSystemWithFailedSelfTest = item.Key;
|
||||
}
|
||||
}
|
||||
|
||||
if (allSelfTestsPassed)
|
||||
{
|
||||
foreach (PowerSupply ps in psList)
|
||||
{
|
||||
_powerSystemNameToPowerModuleMeasurementManagerDict[ps.Name] = new PowerModuleMeasurementManager(ps, _powerOffAndSelfTestConfig);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Perform self test on power supply system
|
||||
/// Self test for each power system takes a while, so we don't want to run self test every time we initialize the power system
|
||||
/// So we only want to run self test under 2 conditions:
|
||||
/// 1. Certain time has elapsed since last power off
|
||||
/// 2. Certain time has elapsed since last self test run ( in the absence of power off time)
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
private Task<SelfTestResult> PerformSelfTestTask(PowerSupply ps)
|
||||
{
|
||||
SelfTestResult result = SelfTestResult.Pass;
|
||||
|
||||
_logger?.Debug($"{this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() for {ps.Name} is running...");
|
||||
|
||||
try
|
||||
{
|
||||
bool performSelfTest = false;
|
||||
const int HOURS_ELAPSED = 2;
|
||||
|
||||
string lastSaveTime = MeasurementManager.PowerSupply.Util.GetLastSavedTime(ps.Name, _powerOffAndSelfTestConfig);
|
||||
|
||||
if (DateTime.TryParse(lastSaveTime, out DateTime dt))
|
||||
{
|
||||
// if this power supply system has been turn off for a certain number of hours, then we want to perform self test on it
|
||||
if (DateTime.Now.Subtract(dt).TotalHours >= HOURS_ELAPSED)
|
||||
{
|
||||
performSelfTest = true;
|
||||
}
|
||||
}
|
||||
else { performSelfTest = true; }
|
||||
|
||||
if (performSelfTest)
|
||||
{
|
||||
_logger?.Info($"{this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() executing self-test for {ps.Name}...");
|
||||
|
||||
result = ps[null].PerformSelfTest();
|
||||
|
||||
if (result == SelfTestResult.Pass)
|
||||
{
|
||||
// save the time of this self test to file
|
||||
MeasurementManager.PowerSupply.Util.SaveTime(ps.Name, null, DateTime.Now.ToString(), _powerOffAndSelfTestConfig);
|
||||
}
|
||||
}
|
||||
else
|
||||
_logger?.Debug($"{this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() skipping self-test for {ps.Name}...");
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger?.Error(ex.Message + "\n" + ex.StackTrace);
|
||||
}
|
||||
|
||||
_logger?.Debug($"{this.GetType().Name}::{System.Reflection.MethodBase.GetCurrentMethod().Name}() for {ps.Name} is exiting...");
|
||||
|
||||
return Task.FromResult(result);
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,38 @@
|
||||
<Project Sdk="Microsoft.NET.Sdk">
|
||||
|
||||
<Import Project="$(SolutionDir)Program.props" />
|
||||
<PropertyGroup>
|
||||
<TargetFramework>net472</TargetFramework>
|
||||
<OutputType>Library</OutputType>
|
||||
<AssemblyName>Raytheon.InstrumentManagers.PowerSupplyManager</AssemblyName>
|
||||
<RootNamespace>Raytheon.InstrumentManagers</RootNamespace>
|
||||
<Product>Power Supply Manager Implementation</Product>
|
||||
<Description>Provide access to the actual power supplies</Description>
|
||||
<GeneratePackageOnBuild>true</GeneratePackageOnBuild>
|
||||
<AllowedOutputExtensionsInPackageBuildOutputFolder>$(AllowedOutputExtensionsInPackageBuildOutputFolder);.pdb</AllowedOutputExtensionsInPackageBuildOutputFolder>
|
||||
<Company>Raytheon Technologies</Company>
|
||||
<Authors>TEEC</Authors>
|
||||
<Copyright>Copyright © Raytheon Technologies $([System.DateTime]::get_now().ToString("yyyy"))</Copyright>
|
||||
|
||||
<!-- Dynamic Versioning (Suitable for Release) -->
|
||||
<!-- <Version>$(Version)$(Suffix)</Version> -->
|
||||
|
||||
<!-- Static Versioning (Suitable for Development) -->
|
||||
<Version>1.0.0</Version>
|
||||
<Configurations>Debug;Release;Deploy</Configurations>
|
||||
</PropertyGroup>
|
||||
|
||||
<ItemGroup>
|
||||
|
||||
<PackageReference Include="NLog" Version="5.0.0" />
|
||||
<PackageReference Include="Raytheon.Configuration" Version="2.6.1" />
|
||||
<PackageReference Include="Raytheon.Configuration.Contracts" Version="2.3.0" />
|
||||
<PackageReference Include="Raytheon.Instruments.InstrumentManager.GeneralInstrumentManager" Version="1.4.1" />
|
||||
</ItemGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\..\Interfaces\PowerSupply\PowerSupply.Contracts.csproj" />
|
||||
<ProjectReference Include="..\..\Raytheon.Common\Raytheon.Common.csproj" />
|
||||
</ItemGroup>
|
||||
|
||||
</Project>
|
||||
@@ -0,0 +1,64 @@
|
||||
/*-------------------------------------------------------------------------
|
||||
// UNCLASSIFIED
|
||||
/*-------------------------------------------------------------------------
|
||||
RAYTHEON PROPRIETARY: THIS DOCUMENT CONTAINS DATA OR INFORMATION
|
||||
PROPRIETARY TO RAYTHEON COMPANY AND IS RESTRICTED TO USE ONLY BY PERSONS
|
||||
AUTHORIZED BY RAYTHEON COMPANY IN WRITING TO USE IT. DISCLOSURE TO
|
||||
UNAUTHORIZED PERSONS WOULD LIKELY CAUSE SUBSTANTIAL COMPETITIVE HARM TO
|
||||
RAYTHEON COMPANY'S BUSINESS POSITION. NEITHER SAID DOCUMENT NOR ITS
|
||||
CONTENTS SHALL BE FURNISHED OR DISCLOSED TO OR COPIED OR USED BY PERSONS
|
||||
OUTSIDE RAYTHEON COMPANY WITHOUT THE EXPRESS WRITTEN APPROVAL OF RAYTHEON
|
||||
COMPANY.
|
||||
|
||||
THIS PROPRIETARY NOTICE IS NOT APPLICABLE IF DELIVERED TO THE U.S.
|
||||
GOVERNMENT.
|
||||
|
||||
UNPUBLISHED WORK - COPYRIGHT RAYTHEON COMPANY.
|
||||
-------------------------------------------------------------------------*/
|
||||
|
||||
using System;
|
||||
using System.Collections;
|
||||
using System.IO;
|
||||
using System.Xml.Serialization;
|
||||
|
||||
namespace Raytheon
|
||||
{
|
||||
/// <summary>
|
||||
/// Serialiable class to store self test and power off time to XML
|
||||
/// and restore info from XML to this class
|
||||
/// </summary>
|
||||
[Serializable]
|
||||
public class PowerSupplySelfTestTime
|
||||
{
|
||||
[XmlAttribute("power_system")]
|
||||
public string _powerSystem { get; set; }
|
||||
|
||||
// date and time of last power off of a power module
|
||||
[XmlAttribute("power_off_time")]
|
||||
public string _powerOffTime { get; set; }
|
||||
|
||||
// date and time of last successful self test
|
||||
[XmlAttribute("self_test_time")]
|
||||
public string _selfTestTime { get; set; }
|
||||
|
||||
/// <summary>
|
||||
/// constructor
|
||||
/// </summary>
|
||||
public PowerSupplySelfTestTime()
|
||||
{
|
||||
_powerOffTime = Raytheon.Common.GeneralConstants.DefaultConfigValue;
|
||||
_powerSystem = Raytheon.Common.GeneralConstants.DefaultConfigValue;
|
||||
_selfTestTime = Raytheon.Common.GeneralConstants.DefaultConfigValue;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// constructor
|
||||
/// </summary>
|
||||
public PowerSupplySelfTestTime(string powerSystem, string powerOffTime, string selfTestTime)
|
||||
{
|
||||
_powerOffTime = powerOffTime;
|
||||
_powerSystem = powerSystem;
|
||||
_selfTestTime = selfTestTime;
|
||||
}
|
||||
}
|
||||
}
|
||||
115
Source/MeasurementManagers/PowerSupplyMeasurementManager/Util.cs
Normal file
115
Source/MeasurementManagers/PowerSupplyMeasurementManager/Util.cs
Normal file
@@ -0,0 +1,115 @@
|
||||
/*-------------------------------------------------------------------------
|
||||
// UNCLASSIFIED
|
||||
/*-------------------------------------------------------------------------
|
||||
RAYTHEON PROPRIETARY: THIS DOCUMENT CONTAINS DATA OR INFORMATION
|
||||
PROPRIETARY TO RAYTHEON COMPANY AND IS RESTRICTED TO USE ONLY BY PERSONS
|
||||
AUTHORIZED BY RAYTHEON COMPANY IN WRITING TO USE IT. DISCLOSURE TO
|
||||
UNAUTHORIZED PERSONS WOULD LIKELY CAUSE SUBSTANTIAL COMPETITIVE HARM TO
|
||||
RAYTHEON COMPANY'S BUSINESS POSITION. NEITHER SAID DOCUMENT NOR ITS
|
||||
CONTENTS SHALL BE FURNISHED OR DISCLOSED TO OR COPIED OR USED BY PERSONS
|
||||
OUTSIDE RAYTHEON COMPANY WITHOUT THE EXPRESS WRITTEN APPROVAL OF RAYTHEON
|
||||
COMPANY.
|
||||
|
||||
THIS PROPRIETARY NOTICE IS NOT APPLICABLE IF DELIVERED TO THE U.S.
|
||||
GOVERNMENT.
|
||||
|
||||
UNPUBLISHED WORK - COPYRIGHT RAYTHEON COMPANY.
|
||||
-------------------------------------------------------------------------*/
|
||||
using Raytheon.Common;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Text;
|
||||
using System.Threading.Tasks;
|
||||
|
||||
namespace Raytheon.MeasurementManager.PowerSupply
|
||||
{
|
||||
/// <summary>
|
||||
/// Define non-specific constants
|
||||
/// </summary>
|
||||
internal static class Util
|
||||
{
|
||||
/// <summary>
|
||||
/// Read from the XML file the time for this power system
|
||||
/// If time of power off is available, we return this time
|
||||
/// If time of last self test run is available, we return this time
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
public static string GetLastSavedTime(string powerSystem, IConfigurationFile powerOffAndSelfTestConfig)
|
||||
{
|
||||
string savedTime = "";
|
||||
string powerOffTime = "";
|
||||
string selfTestTime = "";
|
||||
|
||||
List<PowerSupplySelfTestTime> powerOffEntryListTemp = new List<PowerSupplySelfTestTime>();
|
||||
|
||||
List<PowerSupplySelfTestTime> powerOffEntryList = powerOffAndSelfTestConfig.ReadList<PowerSupplySelfTestTime>(nameof(PowerSupplySelfTestTime), nameof(PowerSupplySelfTestTime), powerOffEntryListTemp);
|
||||
|
||||
foreach (var powerOffEntry in powerOffEntryList)
|
||||
{
|
||||
if (powerOffEntry._powerSystem == powerSystem)
|
||||
{
|
||||
if (DateTime.TryParse(powerOffEntry._powerOffTime, out DateTime dt))
|
||||
powerOffTime = powerOffEntry._powerOffTime;
|
||||
|
||||
if (DateTime.TryParse(powerOffEntry._selfTestTime, out dt))
|
||||
selfTestTime = powerOffEntry._selfTestTime;
|
||||
}
|
||||
}
|
||||
|
||||
if (String.IsNullOrEmpty(powerOffTime))
|
||||
savedTime = selfTestTime;
|
||||
else if (String.IsNullOrEmpty(selfTestTime))
|
||||
savedTime = powerOffTime;
|
||||
else if (!String.IsNullOrEmpty(powerOffTime) && !String.IsNullOrEmpty(selfTestTime))
|
||||
{
|
||||
if (DateTime.TryParse(powerOffTime, out DateTime powerOffDt) && DateTime.TryParse(selfTestTime, out DateTime selfTestDt))
|
||||
{
|
||||
if (DateTime.Compare(powerOffDt, selfTestDt) == 1)
|
||||
savedTime = powerOffTime;
|
||||
else
|
||||
savedTime = selfTestTime;
|
||||
}
|
||||
}
|
||||
|
||||
return savedTime;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Save time of power off or self test event
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
public static void SaveTime(string powerSystem, string powerOffTime, string selfTestTime, IConfigurationFile powerOffAndSelfTestConfig)
|
||||
{
|
||||
List<PowerSupplySelfTestTime> powerOffEntryListTemp = new List<PowerSupplySelfTestTime>();
|
||||
|
||||
List<PowerSupplySelfTestTime> powerOffEntryList = powerOffAndSelfTestConfig.ReadList<PowerSupplySelfTestTime>(nameof(PowerSupplySelfTestTime), nameof(PowerSupplySelfTestTime), powerOffEntryListTemp);
|
||||
|
||||
var entry = powerOffEntryList.Find(b => b._powerSystem == powerSystem);
|
||||
|
||||
if (entry != null)
|
||||
{
|
||||
if (!string.IsNullOrEmpty(powerOffTime))
|
||||
entry._powerOffTime = powerOffTime;
|
||||
|
||||
if (!string.IsNullOrEmpty(selfTestTime))
|
||||
entry._selfTestTime = selfTestTime;
|
||||
}
|
||||
else
|
||||
{
|
||||
PowerSupplySelfTestTime data = new PowerSupplySelfTestTime(powerSystem, powerOffTime, selfTestTime);
|
||||
if (string.IsNullOrEmpty(powerOffTime))
|
||||
data._powerOffTime = Raytheon.Common.GeneralConstants.DefaultConfigValue;
|
||||
|
||||
if (string.IsNullOrEmpty(selfTestTime))
|
||||
data._selfTestTime = Raytheon.Common.GeneralConstants.DefaultConfigValue;
|
||||
|
||||
powerOffEntryList.Add(data);
|
||||
}
|
||||
|
||||
powerOffAndSelfTestConfig.WriteList(nameof(PowerSupplySelfTestTime), nameof(PowerSupplySelfTestTime), powerOffEntryList);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue