[GMA_ATP_001_UUT_STTO] PLACEHOLDER = PLACEHOLDER ;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit ;Type is TWO or FOUR for two wire and four wire measurements ;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#] ; [Card_Name] - must match the name of the switch card defined in the Instrument.xml ;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id] [GMA_ATP_001_UUT_STTO.DMM_RESISTANCE_MEASUREMENTS] R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0 R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0 ; a list of relays that the software will reject if commanded.. ; cannot be empty, put "NONE" if there are no exclusions [GMA_ATP_001_UUT_STTO.RELAY_EXCLUSION_LIST] EXCLUSION_LIST = NONE ;===================================================================================================================== [GMA_ATP_002_UUT_CI] PLACEHOLDER = PLACEHOLDER ;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit ;Type is TWO or FOUR for two wire and four wire measurements ;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#] ; [Card_Name] - must match the name of the switch card defined in the Instrument.xml ;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id] [GMA_ATP_002_UUT_CI.DMM_RESISTANCE_MEASUREMENTS] R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0 R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0 ; a list of relays that the software will reject if commanded.. ; cannot be empty, put "NONE" if there are no exclusions [GMA_ATP_002_UUT_CI.RELAY_EXCLUSION_LIST] EXCLUSION_LIST = NONE ;===================================================================================================================== [AUR_ATP_001_UUT_STTO] PLACEHOLDER = PLACEHOLDER ;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit ;Type is TWO or FOUR for two wire and four wire measurements ;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#] ; [Card_Name] - must match the name of the switch card defined in the Instrument.xml ;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id] [AUR_ATP_001_UUT_STTO.DMM_RESISTANCE_MEASUREMENTS] R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1:-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0 R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0 ; a list of relays that the software will reject if commanded.. ; cannot be empty, put "NONE" if there are no exclusions [AUR_ATP_001_UUT_STTO.RELAY_EXCLUSION_LIST] EXCLUSION_LIST = NONE ;===================================================================================================================== [AUR_ATP_002_UUT_CI] PLACEHOLDER = PLACEHOLDER ;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit ;Type is TWO or FOUR for two wire and four wire measurements ;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#] ; [Card_Name] - must match the name of the switch card defined in the Instrument.xml ;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id] [AUR_ATP_002_UUT_CI.DMM_RESISTANCE_MEASUREMENTS] R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1:-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0 R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0 ; a list of relays that the software will reject if commanded.. ; cannot be empty, put "NONE" if there are no exclusions [AUR_ATP_002_UUT_CI.RELAY_EXCLUSION_LIST] EXCLUSION_LIST = NONE