; =============================================================================================================== ; This name must match the name specified in the Instrument.xml for an instrument of type DIO [PICKERING_DIO_1] LXI_IP_ADDRESS = 192.168.1.15 DEVICE_NUMBER = 15 BUS_NUMBER = 3 SHALL_WE_DRIVE_OUTPUT_UPON_INITIALIZATION = false ; number channels per port NUM_CHANNELS_PER_PORT=8 ; either 0 or 1 as the starting channel index CHANNEL_START_INDEX=0 NUM_OUTPUT_CHANNELS = 32 NUM_INPUT_CHANNELS = 32 ;format is = | ; is either 0 or 1 or 2(Logic Z) [PICKERING_DIO_1.OUTPUT_SIGNALS] SIGNAL_1 = 0|1 SIGNAL_2 = 1|0 ;format is = [PICKERING_DIO_1.INPUT_SIGNALS] SIGNAL_3 = 0 SIGNAL_4 = 0