; =============================================================================================================== ; This name must match the name specified in the Instrument.xml that is associated with the power supply system [STE_POWER_SUPPLY_SYSTEM] SCPI_DEF_FILEPATH = .\InstrumentConfig\KEYSIGHT_SCPI_DEF.ini ETHERNET_ADDRESS = localhost ETHERNET_PORT = 5025 MODULE_DEFINITION = UUT_REF_3_3V, STE_PVM_5V, STE_GU_INTERFACE_RELAYS_25V, STE_GU_INTERFACE_RF_INTERFACE_5V ; 0 means no coupled modules. ; couple means turning on/off any one of the module, turns on/off the others COUPLED_MODULES = STE_PVM_5V, STE_GU_INTERFACE_RELAYS_25V, STE_GU_INTERFACE_RF_INTERFACE_5V ; 0 means no grouped modules. ; group means turning combining 2 or more modules thus acting as one module GROUPED_MODULES = 0 INTERFACE = ETHERNET [STE_POWER_SUPPLY_SYSTEM.UUT_REF_3_3V] INDEX = 1 OCP = 2.0 OVP = 4.0 VOLTAGE_SETPOINT = 3.3 MIN_VOLTAGE = 3.0 MAX_VOLTAGE = 3.75 MAX_CURRENT = 2.0 MIN_CURRENT = -0.25 [STE_POWER_SUPPLY_SYSTEM.STE_PVM_5V] INDEX = 2 OCP = 2.0 OVP = 8.0 VOLTAGE_SETPOINT = 5.0 MIN_VOLTAGE = 4.0 MAX_VOLTAGE = 5.5 MAX_CURRENT = 1.5 MIN_CURRENT = -.25 [STE_POWER_SUPPLY_SYSTEM.STE_GU_INTERFACE_RELAYS_25V] INDEX = 3 OCP = 3.0 OVP = 34.0 VOLTAGE_SETPOINT = 25.0 MIN_VOLTAGE = 22.0 MAX_VOLTAGE = 30.0 MAX_CURRENT = 3.0 MIN_CURRENT = -0.25 [STE_POWER_SUPPLY_SYSTEM.STE_GU_INTERFACE_RF_INTERFACE_5V] INDEX = 4 OCP = 5.0 OVP = 6.5 VOLTAGE_SETPOINT = 5.0 MIN_VOLTAGE = 4.0 MAX_VOLTAGE = 6.3 MAX_CURRENT = 4.5 MIN_CURRENT = -.25 ; =============================================================================================================== ; This name must match the name specified in the Instrument.xml that is associated with the power supply system [UUT_POWER_SUPPLY_SYSTEM] SCPI_DEF_FILEPATH = .\InstrumentConfig\KEYSIGHT_SCPI_DEF.ini ETHERNET_ADDRESS = localhost ETHERNET_PORT = 5026 MODULE_DEFINITION = UUT_P20V, UUT_N20V ; 0 means no coupled modules. ; couple means turning on/off any one of the module, turns on/off the others COUPLED_MODULES = 0 ; 0 means no grouped modules. ; group means turning combining 2 or more modules thus acting as one module GROUPED_MODULES = 0 INTERFACE = ETHERNET [UUT_POWER_SUPPLY_SYSTEM.UUT_P20V] INDEX = 1 OCP = 1.5 OVP = 22.0 VOLTAGE_SETPOINT = 20.0 MIN_VOLTAGE = 19.0 MAX_VOLTAGE = 22.75 MAX_CURRENT = 2.3 MIN_CURRENT = -0.25 [UUT_POWER_SUPPLY_SYSTEM.UUT_N20V] INDEX = 2 OCP = 1.8 OVP = 22.5 VOLTAGE_SETPOINT = 20.0 MIN_VOLTAGE = 18.0 MAX_VOLTAGE = 23.0 MAX_CURRENT = 2.5 MIN_CURRENT = -.25