using System;
|
||||
using Raytheon.Instruments.Dmm;
|
||||
using Raytheon.Units;
|
||||
using System.IO.Ports;
|
||||
using NLog;
|
||||
using Raytheon.Common;
|
||||
|
||||
namespace Raytheon.Instruments
|
||||
{
|
||||
/// <summary>
|
||||
/// A Space Electronics (Squib meter) of the DMM interface
|
||||
/// </summary>
|
||||
public class DMMSquibMeter101SQBRAK : IDmm, IDisposable
|
||||
{
|
||||
#region PrivateMemberVariables
|
||||
|
||||
private string _name;
|
||||
private readonly string _address;
|
||||
private readonly SerialPort _serialPort;
|
||||
private MeasurementFunction _lastType;
|
||||
private double _lastRange;
|
||||
private double _lastResolution;
|
||||
private State _state;
|
||||
private SelfTestResult _selfTestResult;
|
||||
private byte[] _readBuffer;
|
||||
private string versionInfo;
|
||||
|
||||
/// <summary>
|
||||
/// NLog logger
|
||||
/// </summary>
|
||||
private readonly ILogger _logger;
|
||||
/// <summary>
|
||||
/// Raytheon configuration
|
||||
/// </summary>
|
||||
private readonly IConfigurationManager _configurationManager;
|
||||
private readonly IConfiguration _configuration;
|
||||
|
||||
#endregion
|
||||
|
||||
#region PrivateFunctions
|
||||
|
||||
/// <summary>
|
||||
/// Dispose of this objects resources
|
||||
/// </summary>
|
||||
/// <param name="disposing"></param>
|
||||
[System.Diagnostics.CodeAnalysis.SuppressMessage("Microsoft.Usage", "CA2213:DisposableFieldsShouldBeDisposed", MessageId = "_34461A")]
|
||||
protected virtual void Dispose(bool disposing)
|
||||
{
|
||||
try
|
||||
{
|
||||
if (disposing)
|
||||
{
|
||||
if (_state == State.Ready)
|
||||
{
|
||||
IOWrite("RST"); // send reset command
|
||||
IOWrite("LM"); // sets squib meter to local mode (it is set to remote in initilize)
|
||||
|
||||
_serialPort.Close();
|
||||
|
||||
_state = State.Uninitialized;
|
||||
}
|
||||
}
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
try
|
||||
{
|
||||
//ErrorLogger.Instance().Write(err.Message + "\r\n" + err.StackTrace);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
//Do not rethrow. Exception from error logger that has already been garbage collected
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="data"></param>
|
||||
/// <returns></returns>
|
||||
private string ConvertToString(ref byte[] data)
|
||||
{
|
||||
string rsp = System.Text.Encoding.ASCII.GetString(data);
|
||||
return rsp;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Send a command to the squib meter and get the response.
|
||||
/// </summary>
|
||||
/// <param name="commandString">The command to send.</param>
|
||||
/// <returns>The squib meter response as string.</returns>
|
||||
|
||||
private string IOQuery(string commandString)
|
||||
{
|
||||
// Flush squib meter buffer
|
||||
_serialPort.Write("FS");
|
||||
|
||||
// clear our buffer
|
||||
Array.Clear(_readBuffer, 0, _readBuffer.Length);
|
||||
|
||||
// send the data out
|
||||
_serialPort.Write(commandString);
|
||||
|
||||
// read from the response
|
||||
int numBytesRead = _serialPort.Read(_readBuffer, 0, _readBuffer.Length);
|
||||
|
||||
// convert response to a string
|
||||
string rspStr = ConvertToString(ref _readBuffer);
|
||||
|
||||
// split out the command responce from the return data (divided by carriage return)
|
||||
string[] result = rspStr.Split(new string[] { "\n", "\r\n", "<CR>" }, StringSplitOptions.None);
|
||||
|
||||
// Check command responce (0 = OK)
|
||||
if (result[0] == "1")
|
||||
{
|
||||
throw new Exception("Unknown Command");
|
||||
}
|
||||
if (result[0] == "2")
|
||||
{
|
||||
throw new Exception("Command now allowed in present mode");
|
||||
}
|
||||
|
||||
return result[1];
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Sends a serial Command to the instrument.
|
||||
/// </summary>
|
||||
/// <param name="commandString">The serial Command to be sent to the instrument.</param>
|
||||
private void IOWrite(string commandString)
|
||||
{
|
||||
// note each command sent has different return data/status/error formatting, IOWrite is just a direct write
|
||||
// IOQuery will do a read, and return all the data
|
||||
|
||||
// send command to serial port
|
||||
_serialPort.Write(commandString);
|
||||
}
|
||||
|
||||
|
||||
#endregion
|
||||
|
||||
#region PublicFunctions
|
||||
|
||||
/// <summary>
|
||||
/// DMMSquibMeter101SQBRAK factory constructor
|
||||
/// </summary>
|
||||
/// <param name="deviceName"></param>
|
||||
/// <param name="configurationManager"></param>
|
||||
public DMMSquibMeter101SQBRAK(string deviceName, IConfigurationManager configurationManager, ILogger logger)
|
||||
{
|
||||
Name = deviceName;
|
||||
|
||||
_logger = logger;
|
||||
|
||||
_configurationManager = configurationManager;
|
||||
_configuration = _configurationManager.GetConfiguration(Name);
|
||||
|
||||
string comPortName = _configuration.GetConfigurationValue("DMMSquibMeter101SQBRAK", "ComPortName", "COM1");
|
||||
_address = comPortName;
|
||||
int baudRate = _configuration.GetConfigurationValue("DMMSquibMeter101SQBRAK", "BaudRate", 9600);
|
||||
Parity parity = _configuration.GetConfigurationValue("DMMSquibMeter101SQBRAK", "Parity", Parity.None);
|
||||
int dataBits = _configuration.GetConfigurationValue("DMMSquibMeter101SQBRAK", "DataBits", 8);
|
||||
StopBits stopBits = _configuration.GetConfigurationValue("DMMSquibMeter101SQBRAK", "StopBits", StopBits.One);
|
||||
|
||||
_serialPort = new SerialPort(comPortName, baudRate, parity, dataBits, stopBits);
|
||||
_lastType = 0;
|
||||
_lastRange = 0;
|
||||
_lastResolution = 0;
|
||||
_readBuffer = new byte[1000];
|
||||
|
||||
//created in Initialize()
|
||||
|
||||
_state = State.Uninitialized;
|
||||
_selfTestResult = SelfTestResult.Unknown;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The constructor which opens the handle to the DMM and performs a self test on the instrument
|
||||
/// </summary>
|
||||
/// <param name="name">The name of this dmm</param>
|
||||
/// <param name="address">The address of the DMM</param>
|
||||
public DMMSquibMeter101SQBRAK(string name, string comPortName, int baudRate = 9600, Parity parity = Parity.None, int dataBits = 8, StopBits stopBits = StopBits.One)
|
||||
{
|
||||
_name = name;
|
||||
_address = comPortName;
|
||||
_serialPort = new SerialPort(comPortName, baudRate, parity, dataBits, stopBits);
|
||||
_lastType = 0;
|
||||
_lastRange = 0;
|
||||
_lastResolution = 0;
|
||||
_readBuffer = new byte[1000];
|
||||
_logger = LogManager.GetCurrentClassLogger();
|
||||
|
||||
//created in Initialize()
|
||||
|
||||
_state = State.Uninitialized;
|
||||
_selfTestResult = SelfTestResult.Unknown;
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// The Finalizer which will release resources if required
|
||||
/// </summary>
|
||||
~DMMSquibMeter101SQBRAK()
|
||||
{
|
||||
Dispose(false);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
public bool ClearErrors()
|
||||
{
|
||||
throw new NotImplementedException(); // if serial command for clearing errors add here, if not leave as is
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="type"></param>
|
||||
/// <param name="range"></param>
|
||||
/// <param name="resolution"></param>
|
||||
public void ConfigureCurrentMeasurement(MeasurementFunction type, Current range, Current resolution)
|
||||
{
|
||||
throw new NotImplementedException(); // if serial command for clearing errors add here, if not leave as is
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="type"></param>
|
||||
/// <param name="range"></param>
|
||||
/// <param name="resolution"></param>
|
||||
public void ConfigureFrequencyMeasurement(MeasurementFunction type, Frequency range, Frequency resolution)
|
||||
{
|
||||
throw new NotImplementedException(); // if serial command for clearing errors add here, if not leave as is
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="type"></param>
|
||||
/// <param name="range"></param>
|
||||
/// <param name="resolution"></param>
|
||||
public void ConfigureResistanceMeasurement(MeasurementFunction type, Resistance range, Resistance resolution)
|
||||
{
|
||||
if (type != MeasurementFunction.FourWireResistance && type != MeasurementFunction.TwoWireResistance)
|
||||
{
|
||||
throw new Exception("only FourWireResistance or TwoWireResistance is acceptable for param type: " + _lastType.ToString());
|
||||
}
|
||||
|
||||
_lastType = type;
|
||||
_lastRange = range.Ohms;
|
||||
_lastResolution = resolution.Ohms;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="type"></param>
|
||||
/// <param name="range"></param>
|
||||
/// <param name="resolution"></param>
|
||||
public void ConfigureVoltageMeasurement(MeasurementFunction type, Voltage range, Voltage resolution)
|
||||
{
|
||||
throw new NotImplementedException(); // if serial command for clearing errors add here, if not leave as is
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public string DetailedStatus
|
||||
{
|
||||
get
|
||||
{
|
||||
versionInfo = IOQuery("VR");
|
||||
return "Squib Meter version Information (Cage Code | Model Number | Serial Number | Firmware Version | Calibration Date): " + versionInfo;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public bool DisplayEnabled
|
||||
{
|
||||
get
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
|
||||
set
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Dispose of this objects resources
|
||||
/// </summary>
|
||||
public void Dispose()
|
||||
{
|
||||
try
|
||||
{
|
||||
Dispose(true);
|
||||
|
||||
GC.SuppressFinalize(this);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
try
|
||||
{
|
||||
//ErrorLogger.Instance().Write(err.Message + "\r\n" + err.StackTrace);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
//Do not rethrow. Exception from error logger that has already been garbage collected
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public bool FrontPanelEnabled
|
||||
{
|
||||
get
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
|
||||
set
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public InstrumentMetadata Info
|
||||
{
|
||||
get
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public void Initialize()
|
||||
{
|
||||
if (_state == State.Uninitialized)
|
||||
{
|
||||
// Open the port
|
||||
_serialPort.Open();
|
||||
|
||||
// set the squib meter to remote state
|
||||
IOQuery("RM");
|
||||
|
||||
// Ensure continuous reading is off
|
||||
IOQuery("COFF");
|
||||
|
||||
// Flush FIFO buffer
|
||||
IOQuery("FS");
|
||||
|
||||
_state = State.Ready;
|
||||
}
|
||||
else
|
||||
{
|
||||
throw new Exception("expected the state to be Uninitialized, state was: " + _state.ToString());
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public MeasurementFunction MeasurementType
|
||||
{
|
||||
get
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="timeout"></param>
|
||||
/// <returns></returns>
|
||||
public Current MeasureCurrent(int timeout)
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="timeout"></param>
|
||||
/// <returns></returns>
|
||||
public Frequency MeasureFrequency(int timeout)
|
||||
{
|
||||
throw new NotImplementedException();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="timeout"></param>
|
||||
/// <returns></returns>
|
||||
public Resistance MeasureResistance(int timeout)
|
||||
{
|
||||
if (_lastType != MeasurementFunction.FourWireResistance && _lastType != MeasurementFunction.TwoWireResistance)
|
||||
{
|
||||
throw new Exception("only FourWireResistance or TwoWireResistance is acceptable for param type: " + _lastType.ToString());
|
||||
}
|
||||
|
||||
IOQuery("SR"); //todo need to add in range values
|
||||
|
||||
// send serial command to send & read response
|
||||
// set range
|
||||
// set resolution
|
||||
// any other settings that need to be sent (write) before taking measurement
|
||||
|
||||
string response = IOQuery("RV");
|
||||
|
||||
// parse the response //TODO Parse the return data (0= command ok, 1= unknown command, 2= command not allowed in present mode | reading | over range state | wiring error state | calibration state (ok or bad) | hardware state (ok or bad))
|
||||
double rsp = Util.ConvertStringToDouble(response); //if string is only number this is ok, if there are any other char must strip them off
|
||||
|
||||
return Resistance.FromOhms(rsp);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <param name="timeout"></param>
|
||||
/// <returns></returns>
|
||||
public Voltage MeasureVoltage(int timeout)
|
||||
{
|
||||
throw new NotImplementedException(); // if serial command for clearing errors add here, if not leave as is
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public string Name
|
||||
{
|
||||
get { return _name; }
|
||||
set { _name = value; }
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
public SelfTestResult PerformSelfTest()
|
||||
{
|
||||
int testResult = 0;
|
||||
const string BatteryState = "LOW";
|
||||
string result = IOQuery("RV");
|
||||
|
||||
// Set measurement input to backplane after performing self test. Default is front panel.
|
||||
// _dmm.Measurement.In = VTEXDmmInputSelectEnum.VTEXDmmInputSelectInternal;
|
||||
|
||||
if (result == BatteryState)
|
||||
{
|
||||
_selfTestResult = Raytheon.Instruments.SelfTestResult.Fail;
|
||||
throw new Exception("Battery state: " + testResult + " Battery State Message: " + result);
|
||||
}
|
||||
|
||||
_selfTestResult = Raytheon.Instruments.SelfTestResult.Pass;
|
||||
|
||||
return _selfTestResult;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public void Reset()
|
||||
{
|
||||
IOWrite("RST");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public SelfTestResult SelfTestResult
|
||||
{
|
||||
get
|
||||
{
|
||||
return _selfTestResult;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public State Status
|
||||
{
|
||||
get
|
||||
{
|
||||
return _state;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
public void Shutdown()
|
||||
{
|
||||
if (_state == State.Ready)
|
||||
{
|
||||
IOWrite("RST"); // send reset command
|
||||
IOWrite("LM"); // sets squib meter to local mode (it is set to remote in initilize)
|
||||
|
||||
_serialPort.Close();
|
||||
|
||||
_state = State.Uninitialized;
|
||||
}
|
||||
}
|
||||
|
||||
#endregion
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,36 @@
|
||||
<Project Sdk="Microsoft.NET.Sdk">
|
||||
|
||||
<Import Project="$(SolutionDir)Solution.props" />
|
||||
<PropertyGroup>
|
||||
<TargetFramework>net472</TargetFramework>
|
||||
<AssemblyName>Raytheon.Instruments.DMMSquibMeter101SQBRAK</AssemblyName>
|
||||
<Product>DMM Squib Meter 101SQBRAK implementation</Product>
|
||||
<Description>DMM Squib Meter 101SQBRAK implementation</Description>
|
||||
<OutputType>Library</OutputType>
|
||||
|
||||
<!-- Static versioning (Suitable for Development) -->
|
||||
<!-- Disable the line below for dynamic versioning -->
|
||||
<Version>1.0.0</Version>
|
||||
</PropertyGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<PackageReference Include="NLog" Version="5.0.0" />
|
||||
<PackageReference Include="Raytheon.Common" Version="1.0.0" />
|
||||
<PackageReference Include="Raytheon.Instruments.Dmm.Contracts" Version="2.6.0" />
|
||||
</ItemGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\DMMSim\DMMSim.csproj" />
|
||||
</ItemGroup>
|
||||
|
||||
<!-- Copy all *.dlls and *.pdb in the output folder to a temp folder -->
|
||||
<Target Name="CopyFiles" AfterTargets="AfterBuild">
|
||||
<ItemGroup>
|
||||
<FILES_1 Include="$(OutDir)*.dll" />
|
||||
<FILES_2 Include="$(OutDir)*.pdb" />
|
||||
</ItemGroup>
|
||||
<Copy SourceFiles="@(FILES_1)" DestinationFolder="$(HalTempFolder)" />
|
||||
<Copy SourceFiles="@(FILES_2)" DestinationFolder="$(HalTempFolder)" />
|
||||
</Target>
|
||||
|
||||
</Project>
|
||||
@@ -0,0 +1,140 @@
|
||||
// **********************************************************************************************************
|
||||
// DMMSquibMeter101SQBRAKFactory.cs
|
||||
// 2/20/2023
|
||||
// NGI - Next Generation Interceptor
|
||||
//
|
||||
// Contract No. HQ0856-21-C-0003/1022000209
|
||||
//
|
||||
// THIS DOCUMENT DOES NOT CONTAIN TECHNOLOGY OR TECHNICAL DATA CONTROLLED UNDER EITHER THE U.S.
|
||||
// INTERNATIONAL TRAFFIC IN ARMS REGULATIONS OR THE U.S. EXPORT ADMINISTRATION REGULATIONS.
|
||||
//
|
||||
// RAYTHEON PROPRIETARY: THIS DOCUMENT CONTAINS DATA OR INFORMATION PROPRIETARY TO RAYTHEON
|
||||
// COMPANY AND IS RESTRICTED TO USE ONLY BY PERSONS AUTHORIZED BY RAYTHEON COMPANY IN WRITING TO USE IT.
|
||||
// DISCLOSURE TO UNAUTHORIZED PERSONS WOULD LIKELY CAUSE SUBSTANTIAL COMPETITIVE HARM TO RAYTHEON
|
||||
// COMPANY'S BUSINESS POSITION. NEITHER SAID DOCUMENT NOR ITS CONTENTS SHALL BE FURNISHED OR DISCLOSED
|
||||
// TO OR COPIED OR USED BY PERSONS OUTSIDE RAYTHEON COMPANY WITHOUT THE EXPRESS WRITTEN APPROVAL OF
|
||||
// RAYTHEON COMPANY.
|
||||
//
|
||||
// UNPUBLISHED WORK - COPYRIGHT RAYTHEON COMPANY.
|
||||
//
|
||||
// DESTRUCTION NOTICE: FOR CLASSIFIED DOCUMENTS FOLLOW THE PROCEDURES IN DOD 5220.22-M,
|
||||
// NATIONAL INDUSTRIAL SECURITY PROGRAM OPERATING MANUAL, FEBRUARY 2006,
|
||||
// INCORPORATING CHANGE 1, MARCH 28, 2013, CHAPTER 5, SECTION 7, OR DODM 5200.01-VOLUME 3,
|
||||
// DOD INFORMATION SECURITY PROGRAM: PROTECTION OF CLASSIFIED INFORMATION, ENCLOSURE 3,
|
||||
// SECTION 17. FOR CONTROLLED UNCLASSIFIED INFORMATION FOLLOW THE PROCEDURES IN DODM 5200.01-VOLUME 4,
|
||||
// INFORMATION SECURITY PROGRAM: CONTROLLED UNCLASSIFIED INFORMATION.
|
||||
//
|
||||
// CONTROLLED BY: MISSILE DEFENSE AGENCY
|
||||
// CONTROLLED BY: GROUND-BASED MIDCOURSE DEFENSE PROGRAM OFFICE
|
||||
// CUI CATEGORY: CTI
|
||||
// DISTRIBUTION/DISSEMINATION CONTROL: F
|
||||
// POC: Alex Kravchenko (1118268)
|
||||
// **********************************************************************************************************
|
||||
|
||||
using NLog;
|
||||
using Raytheon.Common;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.ComponentModel.Composition;
|
||||
using System.IO;
|
||||
using System.Reflection;
|
||||
|
||||
namespace Raytheon.Instruments
|
||||
{
|
||||
[ExportInstrumentFactory(ModelNumber = "DMMSquibMeter101SQBRAKFactory")]
|
||||
public class DMMSquibMeter101SQBRAKFactory : IInstrumentFactory
|
||||
{
|
||||
/// <summary>
|
||||
/// The supported interfaces
|
||||
/// </summary>
|
||||
private readonly List<Type> _supportedInterfaces = new List<Type>();
|
||||
private ILogger _logger;
|
||||
private readonly IConfigurationManager _configurationManager;
|
||||
private const string DefaultConfigPath = @"C:\ProgramData\Raytheon\InstrumentManagerService";
|
||||
private static string DefaultPath;
|
||||
|
||||
public DMMSquibMeter101SQBRAKFactory(string defaultConfigPath = DefaultConfigPath)
|
||||
: this(null, defaultConfigPath)
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// COECommDeviceInstrumentFactory injection constructor
|
||||
/// </summary>
|
||||
/// <param name="configManager"></param>
|
||||
/// <param name="simEngine"></param>
|
||||
/// <param name="logger"></param>
|
||||
[ImportingConstructor]
|
||||
public DMMSquibMeter101SQBRAKFactory([Import(AllowDefault = false)] IConfigurationManager configManager,
|
||||
[Import(AllowDefault = true)] string defaultConfigPath = null)
|
||||
{
|
||||
DefaultPath = defaultConfigPath;
|
||||
|
||||
if (LogManager.Configuration == null)
|
||||
{
|
||||
var assemblyFolder = Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location);
|
||||
LogManager.Configuration = new NLog.Config.XmlLoggingConfiguration(assemblyFolder + "\\nlog.config");
|
||||
}
|
||||
|
||||
_configurationManager = configManager ?? GetConfigurationManager();
|
||||
_supportedInterfaces.Add(typeof(IDmm));
|
||||
}
|
||||
/// <summary>
|
||||
/// Gets the instrument
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
public IInstrument GetInstrument(string name)
|
||||
{
|
||||
try
|
||||
{
|
||||
_logger = LogManager.GetLogger(name);
|
||||
return new DMMSquibMeter101SQBRAK(name, _configurationManager, _logger);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
throw;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Gets the instrument
|
||||
/// </summary>
|
||||
/// <param name="name"></param>
|
||||
/// <returns></returns>
|
||||
public object GetInstrument(string name, bool simulateHw)
|
||||
{
|
||||
try
|
||||
{
|
||||
_logger = LogManager.GetLogger(name);
|
||||
|
||||
if (simulateHw)
|
||||
return new DMMSim(name, _configurationManager, _logger);
|
||||
else
|
||||
return new DMMSquibMeter101SQBRAK(name, _configurationManager, _logger);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
throw;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Gets supported interfaces
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
public ICollection<Type> GetSupportedInterfaces()
|
||||
{
|
||||
return _supportedInterfaces.ToArray();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// returns configuration based on the predefined path or default path c:/ProgramData/Raytheon/InstrumentManagerService
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
private static IConfigurationManager GetConfigurationManager()
|
||||
{
|
||||
return string.IsNullOrEmpty(DefaultPath) ? new RaytheonConfigurationManager() : new RaytheonConfigurationManager(DefaultPath);
|
||||
}
|
||||
}
|
||||
}
|
||||