Big changes
This commit is contained in:
@@ -0,0 +1,73 @@
|
||||
[GMA_ATP_001_UUT_STTO]
|
||||
PLACEHOLDER = PLACEHOLDER
|
||||
|
||||
;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit
|
||||
;Type is TWO or FOUR for two wire and four wire measurements
|
||||
;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#]
|
||||
; [Card_Name] - must match the name of the switch card defined in the Instrument.xml
|
||||
;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id]
|
||||
[GMA_ATP_001_UUT_STTO.DMM_RESISTANCE_MEASUREMENTS]
|
||||
R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0
|
||||
R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0
|
||||
|
||||
; a list of relays that the software will reject if commanded..
|
||||
; cannot be empty, put "NONE" if there are no exclusions
|
||||
[GMA_ATP_001_UUT_STTO.RELAY_EXCLUSION_LIST]
|
||||
EXCLUSION_LIST = NONE
|
||||
|
||||
;=====================================================================================================================
|
||||
|
||||
[GMA_ATP_002_UUT_CI]
|
||||
PLACEHOLDER = PLACEHOLDER
|
||||
|
||||
;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit
|
||||
;Type is TWO or FOUR for two wire and four wire measurements
|
||||
;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#]
|
||||
; [Card_Name] - must match the name of the switch card defined in the Instrument.xml
|
||||
;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id]
|
||||
[GMA_ATP_002_UUT_CI.DMM_RESISTANCE_MEASUREMENTS]
|
||||
R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0
|
||||
R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0
|
||||
|
||||
; a list of relays that the software will reject if commanded..
|
||||
; cannot be empty, put "NONE" if there are no exclusions
|
||||
[GMA_ATP_002_UUT_CI.RELAY_EXCLUSION_LIST]
|
||||
EXCLUSION_LIST = NONE
|
||||
|
||||
;=====================================================================================================================
|
||||
|
||||
[AUR_ATP_001_UUT_STTO]
|
||||
PLACEHOLDER = PLACEHOLDER
|
||||
|
||||
;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit
|
||||
;Type is TWO or FOUR for two wire and four wire measurements
|
||||
;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#]
|
||||
; [Card_Name] - must match the name of the switch card defined in the Instrument.xml
|
||||
;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id]
|
||||
[AUR_ATP_001_UUT_STTO.DMM_RESISTANCE_MEASUREMENTS]
|
||||
R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1:-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0
|
||||
R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0
|
||||
|
||||
; a list of relays that the software will reject if commanded..
|
||||
; cannot be empty, put "NONE" if there are no exclusions
|
||||
[AUR_ATP_001_UUT_STTO.RELAY_EXCLUSION_LIST]
|
||||
EXCLUSION_LIST = NONE
|
||||
|
||||
;=====================================================================================================================
|
||||
|
||||
[AUR_ATP_002_UUT_CI]
|
||||
PLACEHOLDER = PLACEHOLDER
|
||||
|
||||
;format is name = range|resolution|delay(ms)|scale factor|relays|type|cable and pin id|lower_limit|upper_limit
|
||||
;Type is TWO or FOUR for two wire and four wire measurements
|
||||
;Relay Format: [Card_Name]-[Relay_Channel#],[Card_Name]-[Relay_Channel#]-[Relay_Channel#]
|
||||
; [Card_Name] - must match the name of the switch card defined in the Instrument.xml
|
||||
;Cable and Pin Id Format: [Cable_Id]_[Pin_Id]_[Cable_Id]_[Pin_Id]
|
||||
[AUR_ATP_002_UUT_CI.DMM_RESISTANCE_MEASUREMENTS]
|
||||
R1 = PCODE1|-1|0.001|100|1|PICKERING_SWITCH_1:-56,PICKERING_SWITCH_1-57|TWO|J1_P1_J1_P2|1.0|2.0
|
||||
R2 = PCODE2|-1|0.001|100|1|PICKERING_SWITCH_1-58,PICKERING_SWITCH_1-59|TWO|J1_P3_J1_P4|1.0|2.0
|
||||
|
||||
; a list of relays that the software will reject if commanded..
|
||||
; cannot be empty, put "NONE" if there are no exclusions
|
||||
[AUR_ATP_002_UUT_CI.RELAY_EXCLUSION_LIST]
|
||||
EXCLUSION_LIST = NONE
|
||||
Reference in New Issue